CT SERIESCT SERIESCT SERIESCT SERIESCT SERIESRS-232 INTERFRS-232 INTERFRS-232 INTERFRS-232 INTERFRS-232 INTERFAAAAACECECECECEKITKITKITKITKITFor use wi

Strany 73

2The CT Series RS-232 Accessory is a bidirectional interface which enables the balanceto communicate with a printer or computer that is equipped with

Strany 74

3tor assembly in the balance so thatthe 9-pin connector fits through thehole.4. Fasten the assembly using the twoscriptions for the connector.The bala

Strany 75 - SERVICE INFORMATION

4SETUPSETUPSETUPSETUPSETUPOnce installation is completed, the interface parameters must be entered using theSetup Menu (reference the CT Series Manual

Strany 76

5Fr. 0Fr. 0Fr. 0Fr. 0Fr. 0 START 7 STOP STOPBIT DATA BITS BIT BITFr. 1Fr. 1Fr. 1Fr. 1Fr. 1 START 7 EVEN STOPBIT DATA BITS PARITY BIT BITFr. 2Fr. 2Fr.

Strany 77

6Auto Print IntervalAuto Print IntervalAuto Print IntervalAuto Print IntervalAuto Print IntervalThe Auto Print feature enables the scale to automatica

Strany 78 - SPECIFICATIONS

7DIRECT CONNECTION TO A PRINTERDIRECT CONNECTION TO A PRINTERDIRECT CONNECTION TO A PRINTERDIRECT CONNECTION TO A PRINTERDIRECT CONNECTION TO A PRINTE

Strany 79 - LIMITED WARRANTY

8BY COMPUTER DESCRIPTION BALANCE RESPONSE? Print Display Units The balance responds by sending thecurrent unit indicator and stability status inthe fo

Strany 81

9BY COMPUTER DESCRIPTION BALANCE RESPONSEnnA Set Auto Print Set the Auto Print Interval to “nn” secondsInterval (nn = 0 to 99). Setting the interval t

Strany 82 - CAUTIONCAUTION

OPTIONAL ACCESSORIESOPTIONAL ACCESSORIESOPTIONAL ACCESSORIESOPTIONAL ACCESSORIESOPTIONAL ACCESSORIESOhausPart NumberInterface Cables:Blunt End (User D

Strany 83 - Cable Connections

Instruction ManualPORTABLE AdvancedElectronic BalancesCT SeriesOhaus CorporationOhaus CorporationOhaus CorporationOhaus CorporationOhaus Corporation29

Strany 84 - PRINTING

2NOTICE:NOTICE:NOTICE:NOTICE:NOTICE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLYWITH THE LIMITS FOR A CLASS A DIGITAL DEVICE, PURSUANT TO PART

Strany 85 - CONFIGURING THE PRINT MENU

3TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSINTRODUCTION...

Strany 86 - RS232 COMMAND TABLE

4Custom Units Conversion Factor... 24 Example ...

Strany 87

5INTRODUCTIONINTRODUCTIONINTRODUCTIONINTRODUCTIONINTRODUCTIONThis manual covers installation, operation and troubleshooting for the OHAUS®Portable Adv

Strany 88

6FEATURESPortable Advanced balances contain two display menus which enable you to calibrateand configure the balance for specific operating require

Strany 89

7UNPACKINGUNPACKINGUNPACKINGUNPACKINGUNPACKINGAll Portable Advanced balances are supplied with a weighing platform, AC poweradapter, instruction manu

Strany 90

8Power OptionsPower OptionsPower OptionsPower OptionsPower OptionsThe balance can be operated using 8 AA alkaline batteries (not included), or from an

Strany 92

9Model CT200 Shipping BracketModel CT200 Shipping BracketModel CT200 Shipping BracketModel CT200 Shipping BracketModel CT200 Shipping BracketThe Model

Strany 93

10Low Battery IndicatorParts Counting IndicatorWeighing Unit Indicators& Stability IndicatorsWeigh Below HookWeigh Below HookWeigh Below HookWe

Strany 94

11Checking CalibrationChecking CalibrationChecking CalibrationChecking CalibrationChecking CalibrationBefore using the balance, its calibrationshould

Strany 95

12TaringTaringTaringTaringTaringWhen weighing samples that must be heldin a container, taring enables the balanceto subtract the weight of the contain

Strany 96

13Parts CountingParts CountingParts CountingParts CountingParts CountingParts Counting must be enabled in theSetup menu before using this procedure.Th

Strany 97

14NOTENOTENOTENOTENOTE: If PCErr is displayed, the sample istoo small to provide accurate results withinthe selected parts counting error level (PCEr

Strany 98

15USING MENUS TO CONFIGURE THE BALANCEUSING MENUS TO CONFIGURE THE BALANCEUSING MENUS TO CONFIGURE THE BALANCEUSING MENUS TO CONFIGURE THE BALANCEUSIN

Strany 99

16CALIBRATION MENUCALIBRATION MENUCALIBRATION MENUCALIBRATION MENUCALIBRATION MENUPortable Advanced balances can be calibrated in two ways: Span calib

Strany 100

17Span CalibrationSpan CalibrationSpan CalibrationSpan CalibrationSpan Calibration1. Press and hold until CAL is dis-played, then release it. Balance

Strany 101

18Linearity CalibrationLinearity CalibrationLinearity CalibrationLinearity CalibrationLinearity Calibration1. Press and hold until CAL isdisplayed, t

Strany 103

196. Press . The display will show-C- momentarily, then C followed bythe next mass to be placed on theplatform. Do not disturb the balancewhen -C-

Strany 104

20SETUPRESETYes,NoUNIT SELECTIONggggg, oz, oz t, dwt, lb,t, • (custom), PCDFLT/USRAVERAGING LEVEL0, 11111, 2STABILITY.5d, 1d1d1d1d1d, 2d, 5dAUTO ZEROO

Strany 105

21SETUP MENUSETUP MENUSETUP MENUSETUP MENUSETUP MENUFACTORY SETTINGSFACTORY SETTINGSFACTORY SETTINGSFACTORY SETTINGSFACTORY SETTINGSUnit Selection gA

Strany 106

22 Display Weighing Units and ModesDisplay Weighing Units and ModesDisplay Weighing Units and ModesDisplay Weighing Units and ModesD

Strany 107

23Unit Selection (Cont.)Unit Selection (Cont.)Unit Selection (Cont.)Unit Selection (Cont.)Unit Selection (Cont.)Proceed through all of the weighing un

Strany 108

241. Access the C.Unit submenu.2. The mantissa of the current conver-sion factor will be displayed. This willbe a number between 0 and 9.9999with the

Strany 109

255. Set the value of all digits in the samemanner.6. After the last digit is entered, the dis-play will show the current exponent.The exponent is sho

Strany 110

26IF 1 grain = 0.0647989 gramsTHEN 1 gram =OR 1 gram = 15.43236 grains10.0647989“15432”Number = 1.5432E = 1 (to move the decimal point one place

Strany 111

27Averaging LevelAveraging LevelAveraging LevelAveraging LevelAveraging LevelAveraging level compensates for vibra-tion or excessive air currents. Dur

Strany 112

28Stability RangeStability RangeStability RangeStability RangeStability RangeThe stability range specifies how much adisplayed weight may change while

Strany 114

29Auto-ZeroAuto-ZeroAuto-ZeroAuto-ZeroAuto-ZeroAuto-Zero minimizes the effects of tem-perature changes and shift on the zeroreading. By defining a thr

Strany 115

30Parts Counting Error LevelParts Counting Error LevelParts Counting Error LevelParts Counting Error LevelParts Counting Error LevelThe parts counting

Strany 116

31TIMER SETTINGSTIMER SETTINGSTIMER SETTINGSTIMER SETTINGSTIMER SETTINGSOFFOFFOFFOFFOFFDisables feature.Disables feature.Disables feature.Disables fea

Strany 117

32CALIBRATION LOCK-OUT PROTECTIONCALIBRATION LOCK-OUT PROTECTIONCALIBRATION LOCK-OUT PROTECTIONCALIBRATION LOCK-OUT PROTECTIONCALIBRATION LOCK-OUT PRO

Strany 118

33TROUBLESHOOTINGTROUBLESHOOTINGTROUBLESHOOTINGTROUBLESHOOTINGTROUBLESHOOTINGSYMPTOMNo DisplayLO BAT Indicator- - -Incorrect WeightReadingCalibration

Strany 119

34SERVICE INFORMATIONSERVICE INFORMATIONSERVICE INFORMATIONSERVICE INFORMATIONSERVICE INFORMATIONIf the Troubleshooting section does not resolve or de

Strany 120

35PARTS INFORMATIONPARTS INFORMATIONPARTS INFORMATIONPARTS INFORMATIONPARTS INFORMATIONIf you require replacement parts or would like to purchase acce

Strany 121

36SECURITYSECURITYSECURITYSECURITYSECURITYThe balance can be secured to a stationary object using the Security Locking CableAccessory. The locking cab

Strany 122

37MODELMODELMODELMODELMODEL CT10 CT10 CT10 CT10 CT10CT200CT200CT200CT200CT200CT600CT600CT600CT600CT600CT1200CT1200CT1200

Strany 123

38LIMITED WARRANTYLIMITED WARRANTYLIMITED WARRANTYLIMITED WARRANTYLIMITED WARRANTYOhaus products are warranted against defects in materials andworkman

Strany 125

39Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices worldwide.P/N 77145-03 R0698 © O

Strany 126

1NOTICE:NOTICE:NOTICE:NOTICE:NOTICE: THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FORA CLASS A DIGITAL DEVICE, PURSUANT TO PART

Strany 127

2INTRODUCTIONINTRODUCTIONINTRODUCTIONINTRODUCTIONINTRODUCTIONThe RS232 Interface Accessory is a bidirectional interface which enables PortableAdvanced

Strany 128

37. Place the RS232 circuit board andconnector assembly in the balanceso that the 9-pin connector fits throughthe hole.8. Fasten the Interface assemb

Strany 129

4PRINTINGPRINTINGPRINTINGPRINTINGPRINTINGWhen the Interface is installed,the switch on the balance can initateprint commands as follows:1. Short pres

Strany 130

5CONFIGURING THE PRINT MENUCONFIGURING THE PRINT MENUCONFIGURING THE PRINT MENUCONFIGURING THE PRINT MENUCONFIGURING THE PRINT MENUThe Print menu is u

Strany 131

6<Esc> D<Esc> D<Esc> D<Esc> D<Esc> D Sets all balance menu selections to the factory defaults.PPPPP Print display data i

Strany 132

7SERVICE INFORMATIONSERVICE INFORMATIONSERVICE INFORMATIONSERVICE INFORMATIONSERVICE INFORMATIONFor Service assistance in the United States, please ca

Strany 133

8Ohaus Corporation29 Hanover Road,Florham Park, NJ 07932, USATel: (973) 377-9000,Fax: (973) 593-0359With offices in England, France, Germany, Italy,